AddressMeaningValues
0x50F0E000Interleave Configuration Register

Bits 0-4 indicate which banks should have interleaving enabled

0: banks 0 & 1

1: banks 2 & 3

2: banks 4 & 5

3: banks 6 & 7

4: banks 8 & 9

Note that because odd numbered SIMM banks are empty on 610's, interleaving of RAM SIMMs is not available.

0x50F0E004Bank 0 Configuration Register

Bit 8 indicated bank size. If bit 8 is 0, a bank size of 32MB or smaller will be used. If bit 8 is 1, a 64MB bank size will be used.

Bits 7-0 are address bits 29-22 for where the bank should appear in the physical address space. This also means the minimum bank size is 4MB (4MB = 0x400000, A22 is 1)

0x50F0E008Bank 1 Configuration Register

As above

This bank is empty on machines with 4MB soldered

0x50F0E00CBank 2 Configuration RegisterAs above
0x50F0E010Bank 3 Configuration Register

As above

This bank is empty on 610 machines

0x50F0E014Bank 4 Configuration RegisterAs above
0x50F0E018Bank 5 Configuration Register

As above

This bank is empty on 610 machines

0x50F0E01CBank 6 Configuration RegisterAs above
0x50F0E020Bank 7 Configuration Register

As above

This bank is empty on 610 machines

0x50F0E024Bank 8 Configuration RegisterAs above
0x50F0E028Bank 9 Configuration Register

As above

This bank is empty on 610 machines

0x50F0E02CMemory Size RegisterBits 7-0 contain the address bits 29-22 for the end of physical memory.

...